• RT-PRC021-EN 03/01/2003 Package Gas - Electric Units ...


  •   
  • FileName: rt-prc021-en_03012003.pdf [read-online]
    • Abstract: 80000. 78% 45 - 75. 80000. 64000. 80% 45 - 75. NATURAL. 208-230/3/60. 18. 25 ... 80000. 78% 45 - 75. 80000. 64000. 80% 45 - 75. NATURAL. 460/3/60. 8. 15. 15. 1. 460/3/60. 4 - 51.0 ...

Download the ebook

RT-PRC021-EN
Package
Gas / Electric Units
Convertible Models
YCC018-060
1½ – 5 Ton
Pub. No. 22-1295-05-0303 (EN)
General
Features
T-TOP™
WEATHERGUARD™
corrosion resistant screws
Powder Paint
WATER-SHED Base
High Efficiency
Climatuff® compressor
DuraTuff™ plate fin coil
Single Stage Gas Furnace
Easy Access
© 2003 American Standard Inc. All Rights Reserved 2 22-1295-05-0303 (EN)
Features
and Benefits Contents
Standard Equipment General Features 2
• High Efficiency
IMPACK performance is the highest in the
industry at 16 SEER. Features and Benefits 3
• Climatuff ® compressors
Protection against Standard Equipment 3
chemical, electrical,
and mechanical IMPACK Accessories 4
stresses are built in
for efficiency and a
longer life. The Selection Procedure 5
compressors are
backed by a 5-year Model Number Nomenclature 5
limited warranty, with
an optional warranty
for 5 more years.
(single phase residential use only)
Optional Equipment 6
• Powder Paint
Beautiful high gloss silver gray finish blends General Data 7
with any architectural style, New powder
paint covers surfaces uniformly increasing YCC018 7
protection from rust and corrosion.
• WEATHERGUARD™ YCC024 7
corrosion resistant screws
Holds it all together beautifully. Resists rust
YCC030 7
and corrosion. YCC036 7
• WATER-SHED Base
Superior water integrity is accomplished YCC042 9
with the WATER-SHED base pan having
elevated downflow openings and a YCC048 10
perimeter channel that prevents water
from draining into the ductwork.
YCC060 11
• T-TOP™
Exclusive one piece, solid unit top for Performance Data 12
improved water integrity and easy
component access. Cooling 12
• DuraTuff™ plate fin coil
Refrigeration coils are built with internally Temperature Rise 15
enhanced copper tubing for high efficiency
with less coil area.
Indoor Fan 16
Pressure Drop 19
Optional Equipment 19
Controls 20
Typical Wiring 21
Dimensions 24
• Single Stage Gas Furnace
The furnace features aluminized tubular Mechanical Specifications Options 31
heat exchangers that have demonstrated
their durability in torturous life cycle tests
and fire tests at either 20 or 25 MBTUH per
tube on natural gas or 24 MBTUH on
propane. The heat exchanger is backed by
a 10 year limited warranty with an optional
warranty available for the 11-15th years.
(residential use only)
(continued on page 4)
22-1295-05-0303 (EN) 3
Features and
Benefits
Standard Equipment
• Venting • Convertibility • Service
Induced draft venting reduces combustion IMPACK units are easily converted from All wiring is both numbered and color coded
problems associated with high winds and horizontal to down flow with the removal of thereby reducing training and servicing
combustion panels that have been im- one screw from each panel. Accordingly, costs related to circuit tracing and compo-
properly replaced. the need to stock both dedicated horizon- nents replacements.
• California NOx tal and dedicated down flow models has • Maintenance
The standard unit meets California NOx been eliminated. A plug on the outdoor fan motor allows the
requirements eliminating the inventory prob- • Installation top cover to be removed completely without
lems associated with unique models or kits. The ease of installation and application the hassle of cumbersome wires. The
• One for Us... flexibility exhibited through the design unique service orifice ring allows the indoor
Two for Customer reduce both field time and material. fan motor/blower to be removed as a unit.
Three-try direct spark ignition system • Structure • Corrosion
eliminates pilot related problems and The units are lighter weight through the use The drain pan is engineered material and
provides unsurpassed ignition reliability. of high technology components thereby eliminates the need for coatings and sealers
• Commonality reducing mounting structure requirements to prevent sweating and corrosion. The
The common cabinet among the TCC’s, and difficulty when manhandling. heavy gauge, zinc-coated steel cabinet has
WCX’s, and YCY’s minimizes both the • Handling a weather resistant enamel finish that
training of sales and service personnel and The three-way wooden skid allows for easy stays attractive and protects your invest-
replacement parts inventory. loading between the wheel wells on pickup ment for years.
• Easy Access trucks for transporting to job sites. • Low Ambient Control
Most electrical components can be diag- • Application Standard cooling operation to 55° F. as
nosed and replaced with the removal of one The low profile horizontal duct take-offs shipped, zero degree ambient cooling is
panel that is attached with two screws. eliminate the need for expensive transition accomplished with two kits. One for low
ducts in crawl space applications. cost installations when full tonnage is not
• Flexibility needed. The other kit maintains head
A single curb fits the entire IMPACK line • Duct Flanges pressure and full capacity at zero degrees.
from 1.5 tons through 5 tons thereby Only IMPACK has downflow duct flanges for
providing great installation flexibility on duct attachments that preserve the built-in • Quality and Reliability Testing
shopping malls, factories, schools, and water integrity. We perform a 100% coil leak test at the
other commercial buildings where a mix- factory. The evaporator and condenser coils
match of tonnages and utilities is desired. are leak tested at 200 psig and pressure
tested to 450 psig respectively. In addition
• Shipping the IMPACK designs were rigorously rain
Unit dimensions were carefully selected to tested at the factory to ensure water
provide an attractive aspect ratio and for integrity. Shipping tests are performed to
shipping and handling considerations. determine packaging requirements. Factory
• Good Neighbor shake and drop tests are used as part of the
Most units can be installed flush with the package design process to help assure that
residence or building thereby minimizing the unit will arrive at the job site in top
the ground space required. Blankets of condition. Additionally, all components are
insulation reduce blower noise and energy inspected at the point of final assembly.
losses to the outside environments. Substandard parts and components are
identified and rejected immediately. Every
• Rooftop Mounting unit receives a 100% run test before leaving
The cabinets are physically smaller than the production line to make sure it lives up
most competitive models. This means less to rigorous Trane requirements. We at Trane
intrusive installations on residential rooftops test our designs at our factory and not on
where aesthetics are critical. our customers!
IMPACK Accessories
• Standard Thermostats • Economizer
No special thermostats are needed with The downflow economizer fits inside the unit
IMPACK units. with only the rain hood and barometric relief
• Filter Frame Kit on the outside. Cabling is shipped with the
The IMPACK filter frames accept standard economizer. This cabling is easily routed to
filters and fit inside the unit. The frame kits the control box where it terminates in low
function in either horizontal or downflow duct voltage pigtails. The economizer features a
configurations. fully modulating low voltage motor eliminat-
ing the need for any high voltage wiring.
• UNI-CURB The economizer must be used with the filter
One universal curb fits all the IMPACK frame kit…no return air filter in the econo-
models. It ships knocked down. The curb mizer kit. A dry bulb sensor is shipped with
design incorporates the popular locking tabs the economizer. The downflow economizer
for quick and easy assembly. Full perimeter was not designed for use in horizontal
curbs are also available for all models.
4 22-1295-05-0303 (EN)
Features and
Benefits
IMPACK Accessories
applications. A horizontal only economizer • Propane Kits • Lifting Lug Kit
(which fits externally) is available. The BAYLPKT022A propane kit fits all of the Four reusable lugs in each kit allow units to
• Enthalpy Control Kit IMPACK single stage models. This kit has be easily lifted to rooftop installations. These
For those applications specifying an been constructed for greatest field flexibility lugs snap (no screws required) into slots in
economizer with enthalpy control, this and to minimize the number of parts that the unit drip lip channel.
control can be used in place of the dry bulb have to be discarded. • High Static Motor
sensor or, alternately, two enthalpy controls The BAYLPSS001 propane kit also includes Consists of a higher torque indoor fan
can be paired to provide differential 5 stainless steel burners. motor.
enthalpy control. • Low Ambient Kit • Start Kit
• 25% Fresh Air Kit An EDC provides low ambient cooling to 0° F. The kit mounts in the control box for those
The kit installs over the horizontal return air with some reduced capacity and protects installations specific conditions such as
opening with six screws for downflow require- the system against evaporator icing during excessive voltage drop due to long wires.
ments. It can be used on horizontal air flow other unusual cooling conditions. (This is a capacitor and start relay kit not a
applications by cutting a hole in the return air • Head Pressure Control Kit PTC device.) This kit can be a good
duct or in the unit filter access panel. This kit includes a solid state outdoor motor specification buster!
• Rectangular to Round Duct Kits control, junction box, and wiring. It provides • Coil Guard Kit
The adapter kit can be used in either full capacity down to 0° F. The guards are coated 1"X3" wire grills.
horizontal or downflow applications. These grills will protect the coil from normal
shipping and installation damage.
Selection Procedure
Model Number Nomenclature
1 2 3 4 5 6 7 8 9 10 11 12
Y C C 0 3 6 F 1 M 0 A A
PRODUCT TYPE SERVICE DESIGN
YC = Packaged Gas/Electric MINOR DESIGN SEQUENCE
TC = Packaged Cooling
WC = Packaged Heat Pumps FACTORY INSTALLED OPTIONS
DC = Dual Fuel Heat Pumps EXAMPLES:
0 = No factory installed options
AIRFLOW CONFIGURATION B = Oversize Motor*
C = Convertible N = Filter Frame*
D = Downflow T = Fan Delay Relay*
H = Horizontal * Product Deviation Required
M = Manufactured Housing
P,X= 12 SEER AUXILIARY HEATING CAPACITY
Y = 13-14 SEER L = Low Heat
Z = 15-16 SEER M = Medium Heat
H = High Heat
NOMINAL NET COOLING 0 = No Heat
CAPACITY (MBH)
018 = 1 1/2 Tons ELECTRICAL CHARACTERISTICS
024 = 2 Tons 1 = 208-230/60/1
030 = 2 1/2 tons 3 = 208-230/60/3
036 = 3 Tons 4 = 460/60/3
042 = 3 1/2 Tons W= 575/3/60
048 = 4 Tons D = 380-415/3/50
060 = 5 Tons MAJOR DEVELOPMENT SEQUENCE
F = IMPACK
G = IMPACK Plus
22-1295-05-0303 (EN) 5
Optional
Equipment
OPTIONAL EQUIPMENT FOR PACKAGED UNITS (check mark [✓] indicates accessories included) ✓
Indoor Thermostats — XT300C Prog. 7 Day, Auto/Manual 1 Htg/1 Clg .......................................................................................... TAYSTAT300C [ ]
XT302C Prog. 7 Day, Auto/Manual 2-Stage Htg/CIg w/Econ. .................................................................. TAYSTAT302C [ ]
Electronic 2 Htg/2 Clg (NonProg) ................................................................................................................... TAYSTAT375 [ ]
Outdoor Temp. Sensor (TAYSTAT300C,302C,375) ............................................................................... TAYSENS100A [ ]
Prog. Electronic 5/2 Day, Manual 1 Htg/1 Clg ................................................................................................ TAYSTAT340 [ ]
Electronic 1 Htg/1 Clg (NonProg) ................................................................................................................... TAYSTAT370 [ ]
Wallcover Plate (TAYSTAT370) ............................................................................................................. BAYCOVR100A [ ]
Heat/Cool (Horizontal) Manual 1 Htg/1Clg ......................................................................................................... AY28X092 [ ]
Heat/Cool (Vertical) Manual 1Htg/1Clg ......................................................................................................... BAYSTAT305 [ ]
Thermostat 1H/1C Sub-base Required (BAY28X184,187) ........................................................................... BAYSTAT182 [ ]
Thermostat 2H/2C Sub-base Required (BAY28X184,187) ........................................................................... BAYSTAT183 [ ]
Subbase Auto/Manual Changeover .......................................................................................................... BAYSTAT184 [ ]
Subbase Manual Changeover .................................................................................................................. BAYSTAT187 [ ]
Thermostat 1H/1C Manual Sub-base ........................................................................................................... BAYSTAT008 [ ]
Thermostat 2H/2C Auto Sub-base ................................................................................................................ BAYSTAT010 [ ]
Thermostat 1H/2C Manual Sub-base w/Econ. .............................................................................................. BAYSTAT012 [ ]
Locking Thermostat Cover (Thermostats) ............................................................................................................................................ BAY28X190 [ ]
Anti-short Cycle Timer (Mech. Stats Only) ......................................................................................................................................... BAYASCT001 [ ]
Roof Curb (Flat Roof) Universal 3 ................................................................................................................................................. BAYCURB030A [ ]
Roof Curb (Flat Roof) Universal 3 Acusti-Curb ............................................................................................................................. BAYCURB038A [ ]
Roof Curb Full Perimeter (YCC036F-H,042,048F-M) 3 Acusti-Curb ............................................................................................. BAYCURB033A [ ]
Roof Curb Full Perimeter (YCC048F-H - 060F) 3 Acusti-Curb ...................................................................................................... BAYCURB034A [ ]
Roof Curb Utility Extension Kit (BAYCURB030,038A) ....................................................................................................................... BAYUTIL030A [ ]
Roof Curb Utility Extension Kit (BAYCURB033A) .............................................................................................................................. BAYUTIL033A [ ]
Roof Curb Utility Extension Kit (BAYCURB034A) .............................................................................................................................. BAYUTIL034A [ ]
0-25% Manual Fresh Air Damper (YCC018-42F,048F-M) 1 ......................................................................................................... BAYDMPR040A [ ]
0-25% Manual Fresh Air Damper (YCC048F-H - 060F) 1 ............................................................................................................ BAYDMPR041A [ ]
0-25% Motorized Fresh Air Damper (YCC048F-H - 060F) 1 ........................................................................................................ BAYDMPR050A [ ]
12" Round Duct Adapter (2 per box) (YCC018-042F) ..................................................................................................................... BAYDUCT004A [ ]
14" Round Duct Adapter (1 per box) (YCC018-042F) ..................................................................................................................... BAYDUCT005A [ ]
0-100% Mod Economizer w/Baro. Relief (YCC018-042F,048F-M) 124 ..................................................................................... BAYECON054B [ ]
0-100% Mod. Economizer w/Baro. Relief (YCC048F-H - 060F) 124 ......................................................................................... BAYECON055B [ ]
0-100% Horizontal Economizer 12 .............................................................................................................................................. BAYECON073A [ ]
Enthalpy Control for Economizer (solid state). ................................................................................................................................ BAYENTH001A [ ]
Remote Potentiometer (BAYECON054,055B,073A) .......................................................................................................................... BAYSTAT023 [ ]
Filter Frame (YCC018 - 030F-L) (20 x 20 x 1) 1 ............................................................................................................................. BAYFLTR015A [ ]
Filter Frame (YCC030M,036G-L/M) (20 x 25 x 1) 1. ....................................................................................................................... BAYFLTR012A [ ]
Filter Frame (YCC036F-H,042,048F-M) (20 x 25 x 1) 1 ................................................................................................................. BAYFLTR013A [ ]
Filter Frame (YCC048F-H - 060F) (3-10 x 25 x 1) 1 ....................................................................................................................... BAYFLTR014A [ ]
Filter Frame (YCC030M,036G-L/M) (20 x 25 x 2) 1 ........................................................................................................................ BAYFLTR017A [ ]
Filter Frame (YCC036F-H,042,048F-M) (20 x 25 x 2) 1 ................................................................................................................. BAYFLTR018A [ ]
Filter Frame (YCC048F-H - 060F) (2-16 x 25 x 2) 1 ....................................................................................................................... BAYFLTR019A [ ]
Low Fire Kit (YCC018/024/030/036F-L) ............................................................................................................................................ BAYLOFR001 [ ]
Low Fire Kit (YCC024F-M) ................................................................................................................................................................ BAYLOFR002 [ ]
Low Fire Kit (YCC030/036F-M) ....................................................................................................................................................... BAYLOFR0003 [ ]
Low Fire Kit (YCC036F-H - 042,048F-M) .......................................................................................................................................... BAYLOFR004 [ ]
Low Fire Kit (YCC048-060F) ............................................................................................................................................................. BAYLOFR006 [ ]
High Static Motor (YCC030-042F) (230v/460v) (3/4 HP) ............................................................................................................... BAYHSMT043A [ ]
High Static Motor (YCC030-042F) (208v) (3/4 HP) ........................................................................................................................ BAYHSMT056A [ ]
High Static Motor (YCC048-060F) (230v/460v) (1 HP) .................................................................................................................. BAYHSMT044A [ ]
High Static Motor (YCC048-060F) (208v) (1 HP) ........................................................................................................................... BAYHSMT045A [ ]
LP Conversion Kit ............................................................................................................................................................................ BAYLPKT022A [ ]
LP Conversion Kit (with 5 stainless steel burners) ........................................................................................................................... BAYLPSS001A [ ]
Lifting Lug Kit ..................................................................................................................................................................................... BAYLlFT002A [ ]
Evaporator Defrost Control (Low Ambient Cooling) Kit 6. .............................................................................................................. BAYLOAM011A [ ]
Head Pressure Control (Low Ambient Cool) (208/240/460/575v) Kit 56 ...................................................................................... BAYLOAM323A [ ]
Low Ambient Condenser Motor (208/230v) 5 ............................................................................................................................... BAYMOTR307A [ ]
Low Ambient Condenser Motor (460v) 5 ...................................................................................................................................... BAYMOTR406A [ ]
Quick Start Kit (YCC---F1) .............................................................................................................................................................. BAYKSKT010A [ ]
Crankcase Heater (YCC---F)(230v) 6 ........................................................................................................................................... BAYCCHT003A [ ]
Condenser Coil Guard Kit (YCC018/024/030F-L) .......................................................................................................................... BAYGARD016A [ ]
Condenser Coil Guard Kit (YCC030M/036F-L/M/H) ....................................................................................................................... BAYGARD017A [ ]
Condenser Coil Guard Kit (YCC042/048F-M) ................................................................................................................................ BAYGARD020A [ ]
Condenser Coil Guard Kit (YCC048F-H,060F) .............................................................................................................................. BAYGARD021A [ ]
NOTES:
1 Must use filter frame when economizer/fresh air kit is used. 4 Downflow only.
2 Dry bulb control standard with economizer. 5 Use Low Ambient Condenser Motor With This Kit (except on YCC048-060F).
3 Ships knocked down. 6 Low Ambient cooling requires crankcase heater (BAYCCHT----A).
6 22-1295-05-0303 (EN)
General
Data
MODEL YCC018F1L0B YCC024F1L0B YCC030F1L0B YCC030F1M0AB YCC036F1L0B
RATED VOLTS/PH/HZ 208-230/1/60 208-230/1/60 208-230/1/60 208-230/1/60 208-230/1/60
RATINGS (COOLING) 1
BTUH 18000 23400 29200 29800 35200
Indoor Airflow (CFM) 600 800 1000 1000 1200
Power Input (KW) 1.86 2.55 3.17 3.27 4.02
EER/SEER (BTU/Watt-Hr.) 9.35 / 10.00 9.1 0/ 10.00 9.20 / 10.00 9.10 / 10.00 8.75 / 10.00
Noise Rating No. 1 8.0 8.0 8.0 8.0 8.0
A.G.A. RATINGS (HEATING) 2
(High) Input BTUH 48000 48000 48000 75000 50000
Capacity BTUH 57 37000 37000 37000 60000 40000
AFUE 78% 78% 78% 78% 78%
Temp. Rise °F. (Min./Max.) 35 - 65 35 - 65 35 - 65 35 - 65 15-45
(Low) Input BTUH 40000 40000 40000 60000 40000
Capacity BTUH 57 32000 32000 32000 48000 32000
AFUE 80% 80% 80% 80% 80%
Temp. Rise °F. (Min./Max.) 35 - 65 35 - 65 35 - 65 35 - 65 15-45
Type of Gas 3 NATURAL NATURAL NATURAL NATURAL NATURAL
POWER CONNS. — V/PH/HZ 208-230/1/60 208-230/1/60 208-230/1/60 208-230/1/60 208-230/1/60
Min. Brch. Cir. Ampacity 15.0 17.7 21.5 21.3 26.8
Br. Cir. Max. (Amps) 20 25 30 35 40
Prot. Rtg. Recmd. (Amps) 20 25 30 35 40
COMPRESSOR
No. Used 1 1 1 1 1
Volts/Ph/Hz 200-230/1/60 200-230/1/60 208-230/1/60 208-230/1/60 208-230/1/60
R.L. Amps — L.R. Amps 8 - 48 10.0 - 67 13.3 - 79 13.5 - 79 18.5 - 97
OUTDOOR COIL — TYPE PLATE FIN PLATE FIN PLATE FIN PLATE FIN PLATE FIN
Rows / F.P.I. 2 / 15


Use: 0.0217